About Link 1000 Settings
Series Connection If you are using a single battery bank that consists of two or more batteries connected in series, use the Ah capacity of one battery. For example, if two Trojan
Changing the Battery Capacity Setting
To change the Battery Capacity setting:
1.Press SET until SEL appears in the display.
2.Press SEL three times. The LED comes on and 200 (the default) appears.
3.Press SET and hold it until the value you want appears.
Battery Capacity | Incremental step |
(Ah) | in Ah |
|
|
20 to 40 | 1 |
40 to 100 | 5 |
more than 100 | 20 |
|
|
Note: If you continue to hold SET, the display scrolls faster after four increments. If you go past your battery’s capacity, you have to scroll to 1980Ah. The display then rolls over and begins scrolling up from 20Ah.
Changing the Battery Type Setting
Change the Battery Type setting if you are not using flooded
To change the Battery Type setting:
1.Press and hold SET until SEL appears.
2.Press SEL until Func F10 appears.
3.Press SET to select one of the following battery types: 0 (liquid cell), battery type 1 (gel cell, standard), battery type 2 (gel cell, fast charge), or battery type 3 (AGM – Absorbed Glass Mat).
23