Default: 0 (Liquid Cell)

About Link 1000 Settings

F10 Select Battery Type

Default: 0 (Liquid Cell)

Range: 0 = Liquid Cell; 1 = Gel Cell (standard); 2 = Gel Cell (fast charge); 3 = AGM (Absorbed Glass Mat)

This function sets the appropriate charge and float voltages for the Freedom charger and sets an appropriate Peukert exponent. Gel cell owners can use Type 1 or Type 2, but should consult the battery manufacturer before using Type 2. Type 3 sets Acceptance and Float voltages suited to AGM type batteries.

F11 Turn on Second Battery Voltage Sense

Default: Off

Range: On, Off

When this function is On, two voltages are displayed. When the Volts LED Manual background is on solid, you see the voltage of the monitored battery. If the battery Volts LED Manual background is flashing, the second (starting) battery voltage is being displayed.

If you use this function, keep in mind that the displayed voltage is only an indication of the battery’s state-of-charge if the battery has been at rest for at least eight hours.

A battery with an eight hour at-rest voltage of 12.4 volts or more will probably start an engine. A battery with an eight hour at-rest voltage of 11.1 volts will probably not start an engine, particularly if you have dirty injectors and if the engine doesn’t start right away.

F12 Number of Overload Conditions Experienced

Displays the number of inverter shutdowns since the last high level meter reset. This is primarily a troubleshooting tool.

F13 Number of Inverter Low Battery Shutdowns

Displays the number of inverter low battery shutdowns since the last high level meter reset. This is primarily a troubleshooting tool.