About Link 1000 Settings
F10 Select Battery Type
Default: 0 (Liquid Cell)
Range: 0 = Liquid Cell; 1 = Gel Cell (standard); 2 = Gel Cell (fast charge); 3 = AGM (Absorbed Glass Mat)
This function sets the appropriate charge and float voltages for the Freedom charger and sets an appropriate Peukert exponent. Gel cell owners can use Type 1 or Type 2, but should consult the battery manufacturer before using Type 2. Type 3 sets Acceptance and Float voltages suited to AGM type batteries.
F11 Turn on Second Battery Voltage Sense
Default: Off
Range: On, Off
When this function is On, two voltages are displayed. When the Volts LED is on solid, you see the voltage of the monitored battery. If the battery Volts LED is flashing, the second (starting) battery voltage is being displayed.
If you use this function, keep in mind that the displayed voltage is only an indication of the battery’s
A battery with an eight hour
F12 Number of Overload Conditions Experienced
Displays the number of inverter shutdowns since the last high level meter reset. This is primarily a troubleshooting tool.
F13 Number of Inverter Low Battery Shutdowns
Displays the number of inverter low battery shutdowns since the last high level meter reset. This is primarily a troubleshooting tool.