Xantrex Technology Link 1000 manual F14 mode The RESET and DATA LEDs are orange-yellow

Models: Link 1000

1 74
Download 74 pages 11.15 Kb
Page 42
Image 42
F14 mode:

About Link 1000 Settings

F14 Test Control Panel Display

Default: Off

Range: On while the SET button is pressed when this function is active. Off when SET is released.

This function lets you confirm that the Link 1000 control panel display is operating properly. When you press SET in

F14 mode:

The RESET and DATA LEDs are orange-yellow.

All other LEDs display their normal color.

The Numeric Display reads 188.8.

The display returns to normal when you release SET. Operation of the LOCK and FUNC LEDs is confirmed when power is initially applied to the Link 1000.

F15 Display Software Revision Number

Press SET to display the Software Revision Number.

This function displays the software revision number installed in your Link 1000. Record this number on page 60 in case you need to call Customer Service.

F16 Turn on Active Temperature Compensation

Default: Off

Range: Off, On

Turn this function On if your inverter/charger has a temperature sensor.

Leave this function Off if you are not using a temperature sensor.

When this function is On, the Link 1000 uses the actual battery temperature reported to the Freedom Inverter/Charger by a Heart TC2+2 unit, the Freedom 458 or the Freedom Marine Inverter/Charger temperature sensor.

34

Page 42
Image 42
Xantrex Technology Link 1000 manual F14 mode The RESET and DATA LEDs are orange-yellow