Range: 30° F–120° F (–1.11° C–48.8° C) in 10° increments.

About Link 1000 Settings

F03 Set or Display Ambient Battery Temperatures

Default: If F16 (Active Temperature Compensation) is On, the present battery temperature is displayed in °F. If F16 is Off, the declared battery temperature is displayed.

Range: 30° F–120° F (–1.11° C–48.8° C) in 10° increments.

Set a different value from the default only if the battery environment is significantly different from 70° F (21.11° C) when the batteries are being charged by the Freedom Inverter/Charger.

For more information about battery charging and temperature compensation, see “F07 Set Temperature Coefficient” on page 31.

F04 Toggle Display Between Ah and kWhr

Default: Off

Range: Off = Ah display mode; On = kWhr display mode.

When this function is On, the Ah display is changed to a kilowatt-hour display.

Kilowatt-hours are a very precise measurement of energy removed from or returned to the battery bank. The Link 1000 uses kilowatt-hours to determine whether 100% of the energy consumed from the battery has been returned.

A recalculation of the CEF (Charge Efficiency Factor) is not permitted unless this counter is greater than 0.00 kWhr. This counter counts down during discharge, and the kWhrs consumed are displayed with a negative number. While the battery is charging, the Link 1000 counts back up with 100% efficiency. CEF recalculation is prevented until a positive number is in the kWhr counter. This prevents a premature CEF reset.

30