To test battery capacity:

Charging Functions

Battery Capacity at Various Discharge Rates

Capacity (as a percent of the

Hours to Discharge 20 hour rate)

1089%

578%

366%

145%

To test battery capacity:

1.Charge the battery until the charged parameters are met. This resets Ah to zero.

2.Turn on a load that draws approximately 5% of the expected battery capacity.

3.Check the current by looking at the Amps display. The load should be constant (for example, a light bulb).

4.Put the Link 1000 in Volts Manual background display mode.

5.When the voltage drops to 10.5 volts (or 21 volts if you are testing a 24 volt system), turn the load off. (It should take about twenty hours for the voltage to drop.)

6.Look at the Ah Manual background display. The number of Ah displayed is the actual battery capacity.

If less than twenty hours passed before the voltage fell to 10.5, you can still determine the capacity by completing a simple calculation. For example, assume that you have a 12 volt battery rated at 100 Ah. Apply a 5 amp load. If it only

took ten hours for the voltage to reach 10.5, the Link 1000 would display –50Ah. This number is the 10 hour capacity.

By dividing 50 by 89% (see the preceding table), you determine that the actual 20 hour capacity is 56 Ah. You could repeat the test at 5% of the tested capacity (2.8 amps) to verify the actual capacity.

43