About Link 1000 Settings
Advanced Function Values
The Link 1000 has sixteen advanced functions. The default setting is appropriate for most, and you should not change a value unless you understand the consequence of the change.
Note: If you are monitoring more than one battery:
•Change Function F11, Second Battery Voltage Sense.
•Record the software revision number on page 60. (See “F15 Display Software Revision Number” on page 34.)
How to Enter Setup Mode and Change a Value: Reminder
The procedure for entering Setup mode and changing a value is given on page 20.
F01 Auto Display Scanning
Default: Off
Range: Off, On
When Auto Display Scanning is On, the display automatically scrolls through Volts, Amps, Ah, and Time remaining. Each value is displayed for four seconds.
If Second Battery Voltage Sense (F11) is also on, two voltages are shown. The flashing Volts status LED indicates that the voltage displayed is that of the second battery bank.
F02 Display Sleep
Default: On
Range: On, Off
This function turns off the Numeric Display and the Display Units LEDs. All the other
29