E012

Reading Error Codes

Error

 

Code

Meaning

 

 

E012

Battery voltage sense lead open

 

(Link 1000)

 

Check the fuse or any other connections in the voltage

 

sense lead (blue wire) to the battery.

E013

Spare

 

 

E014

Inappropriate charged voltage selected for the

 

sensed voltage

 

(Link 1000)

 

This code appears if the Charged Voltage parameter is

 

above 20 V and the sensed voltage is below 20 V, or if

 

the sensed voltage is above 20 V and Charged Voltage

 

parameter is below 20 V.

 

This code will help you avoid an incorrect setup.

E015

Incoming AC polarity reversed

 

(Inverter/charger error)

 

Check the incoming AC wiring for reversed polarity

 

(positive and neutral reversed).

 

Consult a qualified electrician if you do not know how

 

to diagnose and correct this condition.

0L

Link 1000 reading out of range

 

(Link 1000)

 

 