Xantrex Technology Link 1000 manual To change the Charged Current Percentage

Models: Link 1000

1 74
Download 74 pages 11.15 Kb
Page 34
Image 34
To change the Charged Current Percentage:

About Link 1000 Settings

To change the Charged Current Percentage:

1.Press and hold SET until SEL appears.

2.Press SEL twice. The Changing the Time Remaining Setting LED comes on and 002 is displayed.

3.Press and hold SET.

The display moves up in one percent steps until 7 percent is displayed. The display then rolls over and starts counting up from 1 percent.

4.Release SET when the appropriate percentage appears.

Changing the Time Remaining Setting

The Link 1000 has four ways of calculating the amount of operating time that remains. You can select:

Present consumption level

A four minute average

A sixteen minute average

A thirty-two minute average

The best setting depends on your type of installation.The four minute average is appropriate for most installations.

To change the Time Remaining setting:

1.Press SET until SEL appears.

2.Press SEL four times until the To change the Time Remaining setting: LED comes on and 001 appears.

3.Press SET until the number you want appears. The display moves up in 1 unit steps with choices of:

000Present consumption

0014 minute average

00216 minute average

00332 minute average

4.Release SET when the value you want appears.

26

Page 34
Image 34
Xantrex Technology Link 1000 manual To change the Charged Current Percentage, To change the Time Remaining setting