3.0 CONFIGURATION
Setting Parameters (continued)
CHARGED Indicator Setup (continued)
14.4
1A
4A | 2A | 3A |
|
|
Set Voltage Level
Voltage LED
Illuminates to Indicate the Voltage Function is Selected
Figure
Setting the CHARGED Indicator Voltage Level
The
Step B Switching OFF the Amperage Detection
1B. Press the SELECT button until the Amperage LED ( A ) is illuminated.
2B. Press the SELECT and RESET buttons simulataniously until the LED display flashes.
3B. Press the RESET button until the display indicates OFF.
4B. Press SELECT button to accept.
The TM500A is now setup to trigger the CHARGED indicator LED () when the voltage level equals or exceeds the value programmed in Step A. When this voltage parameter is met, the CHARGED indicator LED flashes approximately every four seconds.
NOTE: The CHARGED indicator remains ON (solid) even when the batteries are discharging, until reset.
OFF
1B
4B
Set Amps to
OFF
Amperage LED
Illuminates to Indicate
the Amperage
Function is Selected
2B | 3B |
Figure
Turn Amps OFF for VOLTAGE ONLY Detection
18 | © 2001 Xantrex Technology Inc. |