Xantrex Technology TM500A manual Reminders and Indicators continued CHARGED Indicator, Operation

Models: TM500A

1 44
Download 44 pages 16.27 Kb
Page 38
Image 38
Reminders and Indicators (continued)

4.0 OPERATION

Reminders and Indicators (continued)

CHARGED Indicator

The CHARGED indicator ( To reset the CHARGED LED:Resetting the CHARGED IndicatorManual backgroundManual backgroundManual background ) can be programmed to flash every four seconds when specified charging criteria are met. This can be voltage only, voltage and current, or voltage and time. When the programmed conditions are met for a minimum of 30 seconds, the CHARGED indicator flashes. The CHARGED indicator stops flashing and remains ON solid when the “charged” conditions are no longer met (i.e., the current flow is negative (battery discharging) continuously for one minute). The Amp-Hour Meter also resets to zero at this time.

To reset the CHARGED LED:

1.Press the RESET button while the % , V , or A LED is ON.

Reset when any of

these are ON

CHARGED

1

Press RESET to reset the

CHARGED Indicator

Indicator LED

 

Figure 4-6

Resetting the CHARGED Indicator

32

© 2001 Xantrex Technology Inc.

 

P/N 973-0012-01-02 Rev. A 05/01

Page 38
Image 38
Xantrex Technology TM500A manual Reminders and Indicators continued CHARGED Indicator, To reset the CHARGED LED, Operation