![Charger Considerations](/images/new-backgrounds/111285/11128557x1.webp)
3.0 CONFIGURATION
Setting Parameters (continued)
CHARGED Indicator Setup (continued)
Charger Considerations
There are several different types of chargers (relay, taper or three- stage) which can affect the settings and prevent the CHARGE LED from illuminating.
Relay Chargers
Relay type chargers raise the battery to a set voltage level then shut OFF using only voltage as their parameter. Set the TM500A to the voltage only mode and set the voltage slightly below the charger turnoff setting.
Taper Chargers
Taper type chargers raise the battery to a specified voltage and shut OFF when the amperage decreases to a specified level. When using taper type chargers
If the taper charger is a type that charges up to a certain level and then waits for a period of time to determine if the batteries are charged, then set the TM500A to a voltage slightly below the charger’s settings. Set the time a little shorter than the charger’s time period.
Three-stage Chargers
© 2001 Xantrex Technology Inc. | 23 |