Xantrex Technology TM500A 1. H, Step B Setting the Time Duration, Trigger on Voltage and Time

Models: TM500A

1 44
Download 44 pages 16.27 Kb
Page 28
Image 28
Step B Setting the Time Duration

3.0 CONFIGURATION

Setting Parameters (continued)

CHARGED Indicator Setup 1. H (continued)

Step B Setting the Time Duration

1B. Press the SELECT button until the Amperage LED ( A ) is illuminated.

2B. Press the SELECT and RESET buttons simulataniously until the LED display flashes.

3B. Press the RESET button until the display reaches the hour settings. These selections are available following the amperage settings. Select the desired time (in hours or tenths of hours); the voltage must remain at this level to trigger the CHARGED LED.

4B. Press SELECT button to accept. The selectable amperage values are from 0.2H to 2.0H (12 minutes to 2 hours).

The TM500A is now setup to trigger the CHARGED indicator LED (Trigger on Voltage and TimeManual backgroundManual backgroundManual backgroundManual background) when the voltage level equals or exceeds the value programmed in Step A and the current remains positive for the time duration programmed in Step B. When these parameters are met, the CHARGED indicator LED flashes approximately every four seconds. Whenever the current goes negative (discharging), the timer will reset to zero. The CHARGED indicator LED must be manually reset to turn it OFF.

 

Set Time Duration

1. H

Amperage LED

 

Illuminates to

1B

Indicate the

Amperage

 

Function is

 

Selected

4B

2B

3B

Figure 3-10

Trigger on Voltage and Time

22

© 2001 Xantrex Technology Inc.

P/N 973-0012-01-02 Rev.A05/01

Page 28
Image 28
Xantrex Technology TM500A manual 1. H, Step B Setting the Time Duration, Trigger on Voltage and Time, Configuration