5.0 TROUBLESHOOTING

5.0 TROUBLESHOOTING

Symptom

Possible Cause

Solution

LED in INVERTER ON/OFF

J2 plug not plugged into

Plug cable into TM500A and

switch does not light.

TM500A or the inverter.

Inverter's RC4/RC8 remote

 

 

control jack.

 

Inverter does not have a

The inverter remote control

 

compatable Jack.

only operates on models

 

 

equipped with an RC4/RC8

 

 

remote control input.

 

 

 

Voltage displayed on

The TM500A voltage is

Reconfigure the TM500A for

meters is not correct.

configured above 35.0 volts

the correct system voltage

 

for a 12- or 24-volt system.

(see Section 3,

 

 

Configuration, Charged

 

The TM500A voltage is

Indicator Set-up).

 

configured below 35.0 volts

 

 

for a 48-volt system.

 

 

 

 

Battery State-of-Charge

Amp-hour setting is too low.

Reconfigure the amp hours to

displays "FULL" when

 

the correct setting - Battery

voltage is low.

 

bank size (see Section 3,

 

 

Configuration, Setting

 

 

Parameters, Amp Hours).

 

 

 

bLO displays a voltage of

The bLO meter was not

Reconfigure the Low-Voltage

00.0.

configured during set-up, or

Indicator (bLO) for the correct

 

after being disconnected

low-battery voltage (see

 

from the shunt.

Section 3, Configuration,

 

 

Setting Parameters, Low-

 

 

Voltage Indicator).

 

 

 

CHARGED LED continues

VOLTAGE ONLY

Reconfigure the CHARGED

to flash even though the

configuration for the

voltage to an appropriate

current flow is negative

Charged Indicator Setup

value (i.e., 12.6 V for a

(battery discharging)

may be set too low.

12-volt system ), (see Section

continuously for one minute.

 

3, Configuration, Setting

 

 

Parameters, Charged

 

 

Indicator Setup).

 

 

The CHARGED indicator

 

 

must be manually reset to turn

 

 

it OFF.

 

 

 

 

 