C-8 975-0200-01-01
Specifications
Environmental Specifications (Indoor use)
Operating Temperature Range 0 °C to 50 °C, 100% load
Storage Temperature Range –20 °C to 70 °C
Operating Humidity Range 30–90% RH (no condensation)
Storage Humidity Range 10–95% RH (no condensation)
Operating Altitude Up to 6,500 feet (2,000 m)
Installation Category II (IEC 1010-1)
Pollution Degree 2 (IEC 1010-1)
Mechanical Specifications
XTR 850 Watt (W×H×D)
XTR 1700 Watt (W×H×D) 8.4 × 1.7 × 19.0 inch (214 × 43.6 × 483 mm)
16.8 × 1.7 × 19.0 inch (429 × 43.6 × 483 mm without rack mount ears)
Weigh t XTR 850 Watt: 11 lb (5kg); XTR 1700 Watt: 22 lb (10 kg)
Cooling Forced air cooling by internal fans
Regulatory Approvals
Safety CSA 22.2 No. 61010-1 and UL61010-1. Marked with c(UL)us CE (pending) EN61010-1
EMC Complies with EN55022, Class A, FCC Part 15A for conducted emissions
Complies with EN55022, Class A, FCC Part 15A for radiated emissions
Complies with EN61000-4 series of standards for immunity