A-16 975-0200-01-01
SCPI Command Reference
Trigger *TRG Trigger system N/A
Self-Test
Query *TST?
[:]SYSTem[<channel>]:TEST? Perform unit Self Test
(Pass=0). Yes
Wait To
Continue *WAI
[:]SYSTem[<channel>]:WAIT Wait to continue command. N/A
Table A-2 Readback Commands
Function SCPI Command Description Parameter and
Range Query
Read Output
Current [:]MEASure[<channel>][:SCALar]:CURRent
[:DC]? Measure and readback
output current at the
output terminals.
Yes
Read Output
Voltage [:]MEASure[<channel>][:SCALar][:VOLTage]
[:DC]? Measure and readback
output voltage at the
output terminals.
Yes
Table A-3 SCPI Commands for Output Control
Function SCPI Command Description Parame ter and
Range Query
Set Output
latches for the
alarms
[[:]SOURce[<channel>]]:COMBine:CSHare
[:MODE] Sets the output latches for
the alarms. ?|<alarm sum of
latch flags> Yes
Set
(Immediate)
Current Set
point
[[:]SOURce[<channel>]]:CURRent[:LEVel]
[:IMMediate][:AMPLitude] Set current set point
(immediate) ?|<Current Set
Point>|MAXimum|
MINimum
Yes
Table A-1 IEEE 488.2 Commands (Continued)