User Setting Memory Locations

4. The setting has now been saved to the selected user setting memory location.

The SCPI command (s) for these instructions are:

*SAV or [:]SYSTem[<channel>]:SAVE

Recalling User Setting Memory Locations

This feature recalls settings that were previously saved.

 

To load user setting memory locations:

 

1.

Turn the mode control knob to the RCL position.

3

 

RCL is displayed on the output voltage display with a number

 

indicating a preset position on the output current display.

 

 

 

2.

Turn the Rotary knob/Enter button to select a preset position from

 

 

1 to 3.

 

3.

Press the Rotary knob/Enter button.

 

 

rCL done is displayed on the output voltage display.

 

The settings in the selected user setting memory locations have now been applied to the power supply.

The SCPI command (s) for these instructions are:

*RCL

or

[:]SYSTem[<channel>]:RECall

Three user setting memory locations are available and one user setting memory location is saved automatically before AC power shutdown. This user setting memory location will be loaded after AC power is restored.

975-0200-01-01