Status Byte
975-0200-01-01 5-31
5
Operation CompleteThe Operation Complete command causes the power supply to generate
the operation complete message in the Standard Event Status Register
when all pending operations have been finished. See bit 0 in Table 5-10
for more details.
Command:
*OPC, *OPC?
Wait-to-Continue CommandThe Wait-to-Continue command prevents the power supply from
executing any further commands or queries until the no-operation-
pending flag is TRUE.
Command:
*WAI
532 Command Error (CME) Set if an IEEE488.2 syntax error has been detected
by the parser, an unrecognized header was received,
or a group Execute Trigger was entered into the
input buffer inside an IEEE 488.2 program message.
See “Command Error List” on page B–2 for a list of
possible error codes and descriptions.
664 User Request (URQ) Not Implemented
7128 Power ON (PON) Not Implemented
8–15 N/A Reserved Reserved for possible future use by IEEE.
Bit values are reported as zero.
Table 5-10
Standard Event Status Register
Bit Bit Weight Bit Name Description