Local Operation
3-26 975-0200-01-01
Using Over Temperature Protection Lock (OTP)
The OTP lock protects the power supply in the event of an over
temperature alarm. This alarm could be caused by ventilation restriction
or overheating due to fan failure.
Two modes are available:
Auto recovery (OTP OFF) where the power supply turns on again
after cooling down.
Latch mode (OTP ON) where you will need to reset the unit by
turning the front panel power switch to Off and then On again.
If the OTP is activated, the main output will turn off and PRO O7P (over
temperature protection) will blink on the display. The OTP alarm is an
alarm that will auto recover when the temperature falls back into normal
bounds.

Defining the OTP Mode

To define the OTP lock:
1. Turn the mode control knob to the PRT position.
PrO OUP is displayed.
2. Turn the Rotary knob/Enter button until PRO O7P is displayed.
3. Press the Rotary knob/Enter button to display O7P ON or OFF.
4. Turn the Rotary knob/Enter button to change to On or Off.
5. Press the Rotary knob/Enter button.
The SCPI command (s) for these instructions are:
[:]SYSTem[<channel(s)>]:PROTection:LATCh

Resetting in Latch Mode

To reset the power supply if the OTP alarm is tripped and the OTP mode
is set to On (latching enabled), press and hold the Rotary knob/Enter
button for approximately 3 seconds.
The SCPI command (s) for these instructions are:
[:]OUTPut[<channel(s)>]:PROTection:CLEar
[:]SYSTem[<channel(s)>]:PROTection:LATCh