VOLTage Sub-Register
This shows whether the present voltage level is over or under the
specified trip limit.
Table 5-1 5
QUEStionable Status Register
Bit Bit Weight Bit Name Description
0 1 VOLTage Summary of Voltage Register
1 2 CURRent Not Implemented
2 4 TIME Not Implemented
3 8 POWer Not Implemented
416 TEMPerature Summary of Temperature Register
532 FREQuency Not Implemented
664 PHASe Not Implemented
7128 MODulation Not Implemented
8256 CALibration Not Implemented
9512 Not Used Not Used
10 1024 Not Used Not Used
11 2048 Not Used Not Used
12 4096 Not Used Not Used
13 8192 Not Used Not Used
14 16384 Not Used Not Used
15 32768 Not Used Not Used
Table 5-1 6
QUEStionable VOLTage Status Register
Bit Bit Weight Bit Name Description
0 1 OVP Over Voltage Protection
1 2 UVP Under Voltage Protection