CARBURETOR HEATING SYSTEM ELEC – +
ÅThe thermo switch circuit is open. ı The thermo switch circuit is closed.
Test step | Water temperature | Continuity | |||
|
|
| |||
1 | Less than 23 ± 3 ˚C | YES | |||
(73.4 | ± 5.4 ˚F) | ||||
|
| ||||
|
|
| |||
2 | More than 23 ± 3 ˚C | NO | |||
(73.4 | ± 5.4 ˚F) | ||||
|
| ||||
|
|
|
| ||
3 | More than 12 | ± 4 ˚C | NO | ||
(53.6 | ± 7.2 | ˚F) | |||
|
| ||||
|
|
| |||
4 | Less than 12 ± 4 ˚C | YES | |||
(53.6 | ± 7.2 | ˚F) | |||
|
| ||||
|
|
|
|
|
Test steps 1 & 2: Heating phase
Test steps 3 & 4: Cooling phase
WARNING
●Handle the thermo switch with special care.
●Never subject the thermo switch to strong shocks. If the thermo switch is dropped, replace it.
●Check the thermo switch operation.
CARBURETOR HEATER INSPECTION
1.Inspect:
●Carburetor heater resistance Out of specification → Replace.
Tester (+) probe →
Carburetor heater terminal 1
Tester
Carburetor heater body 2
|
|
|
|
| Carburetor | Tester selector |
|
|
|
|
| ||
|
|
|
|
| heater resistance | position |
|
|
|
|
|
|
|
|
|
|
|
| 6 ~ 10 Ω at | Ω ⋅ 1 |
|
|
|
|
| 20 ˚C (68 ˚F) | |
|
|
|
|
|
| |
|
|
|
|
|
|
|
6 - 8