CHAPTER2 Ethernet Unit

2-8 TELNET dedicated parameters

To ensure reliable TELNET communications that match customer system settings, the Ethernet unit can be used with TELNET dedicated parameters explained in this section.

2-8-1 TELNET dedicated parameters: Setup method 1

To set up TELNET dedicated parameters, use the procedure below. (User name and password settings are not included.)

1)Press F3 (SYS) on the initial menu screen.

2)Press F4 (next) to switch the function display and then press F2 (OPT).

3) Press F4 (next) a few times until the pa- rameter you want to set appears, and then press that function key.

[MENU] select menu

1EDIT2OPRT3SYS 4MON

[SYS] select menu

1SAFE2OPT 3UTL 4next

[SYS-OPT] select menu

1PORT2ECHO3TOUT4next

4)The currently set data now appears. To change this setting, enter the figure you want with the number pad keys. When fin-

ished, press the key.

5)The screen returns to the previous display in step 4).

[SYS-OPT-PORT] port No

=23

range 065535

[SYS-OPT-PORT] port No

= 3000

range 065535