Maintenance and care

 

Shift cable (shift lever end)

Grease quantity:

 

 

Initial 10 hours or 1 month:

 

33.0–35.0 cm³ (1.12–1.18 US oz)

 

(1.16–1.23 Imp.oz)

 

Every 100 hours or 12 months:

 

6.0–8.0 cm³ (0.20–0.27 US oz)

 

(0.21–0.28 Imp.oz)

Shift cable (reverse gate end)

Intermediate housing

Fill the intermediate housing with water-re- sistant grease through the grease nipple using a grease gun.

1

1Grease nipple

EJU34451

Checking the battery

Check the level of the battery electrolyte and make sure that the negative (–) and positive

(+) battery leads are tightened securely.

EWJ00790

WARNING

Battery electrolyte is poisonous and dan- gerous, causing severe burns, etc. Electrolyte contains sulfuric acid. Avoid contact with skin, eyes, or clothing.

Antidotes

External: Flush with water.

Internal: Drink large quantities of water or milk. Follow with milk of magnesia, beaten egg, or vegetable oil. Call a physician im- mediately.

Eyes: Flush with water for 15 minutes and get prompt medical attention.

Batteries produce explosive gases. Keep sparks, flames, cigarettes, etc., well away. If using or charging the battery in an enclosed space, make sure that it is well ven-

99