140
Using the Recall Safe function
LS9-16/32 Owner’s Manual

“Recall Safe” is a function that excludes only specific parameters/channels from Recall opera-

tions. This differs from the Focus settings ( p. 139) made for individual scenes in that Recall

Safe settings are common to all scenes.

1In the DISPLAY ACCESS section, press the
[CHANNEL JOB] key repeatedly to access
the RECALL SAFE screen.
In this screen you can make settings for the Recall
Safe function. The window contains the following
items.
1CH RECALL SAFE field
The channels for which Recall Safe is turned on are
highlighted in this field. If you turn on the SET BY
SEL button, you can turn on Recall Safe for a channel
simply by pressing the [SEL] key of that channel.
BCLEAR ALL button
This clears all Recall Safe settings for the channels
that are highlighted in the CH RECALL SAFE field.
CGLOBAL field
In this field, global parameters (parameters that affect
the entire mix, and are not specific to individual chan-
nels) can be excluded from Recall operations.
DSAFE PARAMETER field
Here you can switch Recall Safe on/off for each chan-
nel, and choose the parameters that will be excluded
from Recall operations. If you select a channel by
pressing its [SEL] key, the Recall Safe settings of that
channel will be shown in this field.
EAPPLY TO ALL INPUT button / APPLY TO
ALL OUTPUT button
If these buttons are on when you operate the SAFE
PARAMETER buttons, the changes will apply to all
input (or output) channels. This is convenient when
you want to make settings for all channels in a single
action.
2To select the channel whose Recall Safe
settings you want to edit, press the corre-
sponding [SEL] key.
The corresponding channel in the CH RECALL SAFE
field will be enclosed by a white border. (However,
Recall Safe is not yet enabled at this point.) At this
time, the SAFE PARAMETER field will show the
Recall Safe settings of the selected channel.
Using the Recall Safe function
[CHANNEL JOB] key
LS9-16
LS9-32
1
2
4
5
3
1
2
4
5
3
•You can also access this screen from the SAFE field of the
SELECTED CH VIEW screen (
p. 88).
HINT
• If the CH RECALL SAFE field’s SET BY SEL button is on,
Recall Safe will be enabled when you press the [SEL] key,
and the corresponding channel will be highlighted in the CH
RECALL SAFE field. You can select parameters as described
in step 3 even after turning Recall Safe on.
HINT