MIDI Data Format
263
LS9-16/32 Owner’s Manual
Appendices
4.1.2 Format (PARAMETER REQUEST)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS are matched. The data will be
echoed when [PARAMETER CHANGE ECHO] is on. The corresponding
parameter will be changed via PARAMETER CHANGE immediately the data is
received.
4.1.3 Data category
4.2 FUNCTION CALL – LIBRARY STORE, RECALL –
4.2.1 Format (PARAMETER CHANGE)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS are matched. The data will be
echoed when [PARAMETER CHANGE ECHO] is on. The corresponding
parameter will be changed immediately the data is received.
Transmission
Data will be transmitted with the [Device Number] (MIDI CH) in [Tx CH]
when [PARAMETER CHANGE Tx] is on.
4.2.2 Function Name
4.2.3 Module Name
STATUS 11110000 F0 System exclusive message
ID No. 01000011 43 Manufacture’s ID number (YAMAHA)
SUB STATUS 0001nnnn 3n n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E Digital mixer
MODEL ID 00010010 12 LS9
DATA Category 0ccccccc cc
DATA 0eeeeeee eh Element no High.
0eeeeeee el Element no Low.
0iiiiiii ih Index no High.
0iiiiiii il Index no Low.
0ccccccc ch Channel no High.
0ccccccc cl Channel no Low.
EOX 11110111 F7 End of exclusive
DATA CATEGORY NAME
0x01 00000001 Current Scene/Setup/Backup/
User Setup Data
STATUS 11110000 F0 System exclusive message
ID No. 01000011 43 Manufacture’s ID number (YAMAHA)
SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E Digital mixer
MODEL ID 00010010 12 LS9
DATA CATEGORY 00000000 00 OTHER DATA
FUNCTION NAME 01001100 "L" (ASCII CODE)
01101001 "i"(ASCII CODE)
01100010 "b"(ASCII CODE)
0fffffff ff (ASCII CODE)
0fffffff ff (ASCII CODE)
0fffffff ff (ASCII CODE)
0fffffff ff (ASCII CODE)
0fffffff ff (ASCII CODE)
MODULE NAME 0mmmmmmm mm (ASCII CODE)
0mmmmmmm mm (ASCII CODE)
0mmmmmmm mm (ASCII CODE)
0mmmmmmm mm (ASCII CODE)
0mmmmmmm mm (ASCII CODE)
0mmmmmmm mm (ASCII CODE)
0mmmmmmm mm (ASCII CODE)
0mmmmmmm mm (ASCII CODE)
DATA 0nnnnnnn nh Number High
0nnnnnnn nl Number Low
0ccccccc ch Channel High
0ccccccc cl Channel Low
EOX 11110111 F7 End of exclusive
FUNCTION NAME
Store “LibStr__”
Recall “LibRcl__”
Unknown Factor Store “LibUnStr”
Unknown Factor Recall “LibUnRcl”
Store Undo (only Scene) “LibStrUd”
Recall Undo (only Scene) “LibRclUd”
MODULE NAME
Scene “SCENE___”
Input EQ “INEQ____”
Output EQ “OUTEQ___”
Dynamics “DYNA____”
GEQ “GEQ_____”
Effect “EFFECT__”
Function Number channel*1) tx/rx
“LibStr__“ SCENE 1- 300 *5) tx/rx
INPUT EQ LIB 41- 199 *1) tx/rx
OUTPUT EQ LIB 4- 199 *2) *3) *4) tx/rx
Dynamics LIB 42- 199 *1) *2) *3) *4) *8) tx/rx
GEQ LIB 1- 199 *6) tx/rx
EFFECT LIB 58- 199 *7) tx/rx
“LibUnStr“ SCENE 1- 300 0 tx
INPUT EQ LIB 41- 199 0 tx
OUTPUT EQ LIB 4- 199 0 tx
Dynamics LIB 42- 199 0 tx
GEQ LIB 1- 199 0 tx
EFFECT LIB 58- 199 0 tx
“LibRcl__“ SCENE 0- 300 *5) tx/rx
INPUT EQ LIB 1- 199 *1) tx/rx
OUTPUT EQ LIB 1- 199 *2) *3) *4) tx/rx
Dynamics LIB 1- 199 *1) *2) *3) *4) *8) tx/rx
GEQ LIB 0- 199 *6) tx/rx
EFFECT LIB 1- 199 *7) tx/rx
“LibUnRcl“ SCENE 0 *5) tx
INPUT EQ LIB 0 *1) tx
OUTPUT EQ LIB 0 *2) *3) *4) tx
Dynamics LIB 0 *1) *2) *3) *4) *8) tx
GEQ LIB 0 *6) tx
EFFECT LIB 0 *7) tx
“LibStrUd“ SCENE 0 0
“LibRclUd“ SCENE 0 0
*1)0:CH1–63:CH64
64:ST IN 1L–71:ST IN 4R
*2)256:MIX1–271:MIX16
*3)512:MATRIX1–519:MATRIX8
*4)1024:STEREO L–1026:MONO(C)
*5)512:will be used if the recalling or storing data is only one.
*6)0:RACK1–7:RACK8 If a GEQ is mounted in RACK 1–8.
*7)0:RACK5–3:RACK8 If an effect is mounted in RACK 5–8.
*8)1280:CH 1–1343:CH 64
1344:STIN 1L–1351:STIN 4R
(Dynamics2)