210
Using cascade connections
LS9-16/32 Owner’s Manual
1In the DISPLAY ACCESS section, press the
[SETUP] key repeatedly to access the SYS-
TEM SETUP screen.
1CASCADE OUT button
2In the MIXER SETUP field located at the
lower part of the SYSTEM SETUP screen,
move the cursor to the CASCADE OUT but-
ton and press the [ENTER] key.
The CASCADE OUT PATCH popup window will
appear. This window contains the following items.
1Port select popup buttons
These buttons access an OUTPUT PORT SELECT
popup window where you can select the output port
for each bus.
BCASCADE LINK PORT field
When using the Cascade Link function, this specifies
the port by which control signals will be transmitted
and received between the two LS9 consoles.
CCASCADE COMM LINK field
Here you can select the parameters and events that will
be linked by the Cascade Link function.
3Move the cursor to the port select popup
button for the bus whose port you want to
assign, and press the [ENTER] key.
The OUTPUT PORT SELECT popup window will
appear.
[ OUTPUT PORT SELECT popup window for
the LS9-32 ]
[ OUTPUT PORT SELECT popup window for
the LS9-16 ]
This popup window contains the following items.
1Port select buttons
These buttons select the output port for the selected
bus.
BSlot select tabs (LS9-32 only)
These tabs select slots 1/2.
4Use the port select buttons {slot select tabs
and port select buttons} to select an output
port, move the cursor to the CLOSE button
and press the [ENTER] key.
The port will be assigned to the bus you selected in
step 3.
5Repeat steps 3 and 4 to assign output ports
to other buses.

Operations on the cascade slave

LS9

LS9-32
1
1
2
3
2
1
1
•You can’t assign two or more buses to the same output port. If
you select a bus to which a signal route has already been
assigned, the previous assignment will be cancelled.
NOTE