M7CL Owner’s Manual
Fixing the channels or DCA groups of the Centralogic section
104

If desired, you can fix the channels or DCA groups controlled by the faders, [ON] keys, meters,

[CUE] keys, and [SEL] keys of the Centralogic section, and switch between groups of eight chan-

nels for control in the OVERVIEW screen.

In this case, the multifunction encoders will control a different set of eight channels than the Cen-

tralogic section’s faders and [ON] keys.

1In the NAVIGATION KEYS section, press the
navigation key for the channels or DCA
group you want to fix in the Centralogic
section, and hold it down for two seconds
or longer.
The LED of the navigation key will blink. The blink-
ing indicates that the corresponding channels or DCA
groups are now fixed to the Centralogic section.
2Press a navigation key (other than the
[DCA] key) to select the eight channels you
want to control in the OVERVIEW screen.
The LED of the navigation key you selected in step 2
will light. The lit status indicates that the correspond-
ing channels can be controlled in the OVERVIEW
screen and by the multifunction encoders.
The following illustration shows the example of when
the DCA groups are fixed to the Centralogic section,
and INPUT channels 1–8 are controlled in the OVER-
VIEW screen.
3As desired, use the navigation keys to
switch the group of eight channels con-
trolled by the OVERVIEW screen, multifunc-
tion encoders.
4To release the channels or DCA groups that
were fixed to the Centralogic section, press
the navigation key you operated in step 1
once again, and hold it down until the navi-
gation key LED changes from blinking to lit.
When the navigation key LED changes to being lit, its
channels or DCA groups will be assigned to both the
Centralogic section and the OVERVIEW screen.
Fixing the channels or DCA groups of the Centralogic section
•You cannot operate DCA groups in the OVERVIEW
screen using the multifunction encoders. For this rea-
son, pressing the [DCA] key in step 2 will have no
effect.
NOTE
Control INPUT
channels 1–8 in the
OVERVIEW screen.
Control DCA
groups 1–8.