M7CL Owner’s Manual
Connecting SB168-ES units to the M7CL-48ES using the Stage Box Setup function
242
When you connect one M7CL-48ES to up to three SB168-ES units, using the Stage Box Setup
function enables you to set up the EtherSound patches and word clock without using AVS-
ESMonitor.
For more information on setting up patches, refer to “Connecting SB168-ES units to the M7CL-
48ES using the STAGE BOX SETUP function” ( p. 43).
You can use the Stage Box Setup function in the EXT-ES HA field in the VIRTUAL RACK window.
Use one of the following two methods to display the EXT-ES HA field:
•Press the SETUP button, then press the STAGE BOX SETUP button in the SETUP screen.
•Press the RACK button, press the EXT-ES HA tab in the VIRTU AL RA CK window, then press
the SB168-ES button in the VIEW field.
1AUTO CONFIGURE button
This button switches the automatic configuration of Ether-
Sound patches on and off. When this button is switched
on, the master clock will be set to INT 48kHz (in a daisy
chain connection) or to EtherSound (48kHz) (in a ring
connection).
If you want to change the EtherSound setting in AVS-
ESMonitor or if you want the M7CL-48ES or SB168-ES
to start up with the settings made in AVS-ESMonitor,
switch this button off.
BDAISY CHAIN / RING buttons
Use these buttons to switch to DAISY CHAIN (daisy
chain connection) or RING (ring connection) setup,
according to the connection with the SB168-ES.
For more information on daisy chain and ring connec-
tions, please refer to “Connecting SB168-ES units to the
M7CL-48ES using the STAGE BOX SETUP function” (
p. 43).
You can connect the M7CL-48ES and SB168-ES units in
a daisy chain or ring connection. If the connection type
and the Stage Box Setup data do not match, the patch and
word clock settings will not work properly.
1Press the AUTO CONFIGURE button to turn
it off (the button indicator will turn off).
2Press the DAISY CHAIN button for a daisy
chain connection. Press the RING button
for a ring connection.
3Press the AUTO CONFIGURE button to turn
it on (the button indicator will light).
A setup confirmation dialog box is displayed.
4Confirm that the setting is correct, then
press the OK button.
Connecting SB168-ES units to the M7CL-48ES using the Stage Box Setup function
1 2
The word clock setting cannot be changed if the AUTO CONFIG-
URE button is turned ON.
NOTE

Changing settings to suit the

connection

Also, be sure to change the SB168-ES dip switches according to
the connection type. (
p. 43)
NOTE