M7CL Owner’s Manual

Electrical characteristics

296
Dynamic Range Fs= 44.1 kHz or 48 kHz
* Dynamic range are measured with a 6 dB/octave filter @12.7 kHz; equivalent to a 20 kHz filter with infinite dB/octave attenuation.
Sampling Frequency
Input Output RL Conditions Min. Typ. Max. Unit
INPUT 1-48 <M7CL-48>
INPUT 1-32 <M7CL-32> OMNI OUT 1-16 600 AD + DA, GAIN: Min. 108
dB
ST IN 1-4 [L,R] <M7CL-32/48>
OMNI IN 1-8 <M7CL-48ES>
OMNI OUT 1-16 <M7CL-32/48>
OMNI OUT 1-8 <M7CL-48ES> 600 AD + DA, GAIN: Min. 108
OMNI OUT 1-16 <M7CL-32/48>
OMNI OUT 1-8 <M7CL-48ES> 600 DA Converter 110
Parameter Conditions Min. Typ. Max. Unit
External Clock Frequency Range <M7CL-32/48> 39.69 50.88
kHz
Frequency Range <M7CL-48ES> 43.00 49.20
Internal Clock
Frequency Word Clock : Int 44.1 kHz 44.1
Word Clock : Int 48 kHz 48
Accuracy Word Clock : Int 44.1 kHz 50 ppm
Word Clock : Int 48 kHz
Jitter Word Clock : Int 44.1 kHz 5ns
Word Clock : Int 48 kHz