42 MIXING Display Functions
02R User’s Guide
The third METER page contains the meters for the bus outs, aux sends, and
the stereo output, plus the master faders for the bus outs and aux sends,
and appears when one of these channels is selected.
Peak Hold
The Peak Hold function can be turned on and off from any page of the
METER display function. Clear the peak hold levels by turning the Peak
Hold off (select the PEAK HOLD icon and press the [ENTER] button) or by
selecting another display function. The dedicated control room output
meter peak hold is not affected when other display functions are selected.
Meter Source Points
The following table lists the meter signal source points:
Note: When the 02R reaches CLIP, digital signal distortion occurs. You must
ensure this does not happen. Digital distortion is very unpleasant sounding. There
are a several things you can do. If CLIP is reached, but the corresponding PEAK
indicator is not illuminated, you need to attenuate the channel slightly with the
/ATT display function (see “Phase and Attenuation” on page 32 of the User’s
Guide). Otherwise, back off the GAIN control a little (see “GAIN Controls” on
page 27 of the User’s Guide).
Signal Source Points
MIC/LINE 1–24 Post GAIN and
A/D, Pre EQ Post EQ Post Fader
TAPE 1–16, EFF1, EFF2 Pre EQ Post EQ Post Fader
BUS 1–8, AUX 1–8, STE-
REO OUT Pre Fader Post Fader
Setting the Bus Out and Aux Send Levels
1. Use the CURSOR buttons
to select one of the
fader icons.
2. Adjust the level by
rotating the encoder
wheel.