Installing Options 235
02R User’s Guide
Wordclock Selection
1. Power on your DA-88 modular digital multitrack recorder and
then the 02R.
It is always important to observe the correct order for powering up
equipment in a studio. Start with the DA-88 and mastering recorders
and the signal processors, then the 02R, and finally the monitoring
amplifiers and other downstream gear.
2. Use the [DIGITAL I/O] button to locate the DIGITAL I/O 1/5 page.
If the card was installed properly, the 02R should will identify it in the
appropriate slot. The TDIF-1 digital I/O card (CD8-TDII) can be
installed in any slot. You should install the first two cards in SLOT1
and SLOT2 in order to access the direct out lines.
3. Use the CURSOR buttons to select the wordclock source.
Use the CURSOR buttons to select the W.CLK IN box and press the
[ENTER] button.
The current wordclock source is indicated by a highlighted icon. See
“Word Clock Select” on page 188 of the User’s Guide for further details.
Note: If the W.CLK IN box is not showing a proper wordclock input (no
discrepancy between the input and selected wordclock frequencies), check
the BNC cable between the WORD SYNC OUT connector on the DA-88
and the WORD CLOCK IN connector on the 02R.Check that the DA-88 is
powered on.