®®l›c‹à
3ULQWHU,QWHUIDFH7HFKQLFDO,QIRUPDWLRQ
5656566HULDO'DWD3RUWThe connections for these standard interfaces are made through the DB-25S connector on the rear panel. For all RS-232 input and output signals, the printer follows both the Electronics Industries Association’s (EIA) RS-232 specifications and the Consultative Committee for International Telegraph and Telephone (CCITT) V.24 standard signal level specifications.
The following table shows the pin configuration and function of the rear panel serial data connector on the printer.
| Pin No. | Description |
1 | FG (frame ground) for cable shield |
| |
2 | TXD (RS-232 transmit data) output from printer |
| |
3 | RXD (RS-232 receive data) input to printer |
| |
4 | RTS (RS-232 request to send) output from printer |
| |
6 | DSR (data set ready) input to printer |
| |
7 | SG (signal ground) for RS-232 |
| |
9 | +5 VDC source output (1 Amp maximum) |
| |
11 | SGR (signal ground reference) for RS-422/RS-485 |
| |
13 | Data input B(-); RS-422/RS-485 |
| |
14 | Data output B(-); RS-422/RS-485 |
| |
16 | Data input A(+); RS-422/RS-485 |
| |
19 | Data output A(+); RS-422/RS-485 |
| |
20 | DTR (RS-232 data terminal ready) output from printer |
| |
| NOTE: Pins 5, 8, 10, 12, 15, 17-18, 21-25 are unused and unterminated. |
| |