Press

Display Shows

Action/Explanation

 

 

Setting the Applicator Port: Press the RIGHT or LEFT

 

 

BLACK OVAL key to display other choices.

 

 

Default: Off

 

 

Selections: Off, mode 1, mode 2, mode 3, mode 4

 

 

Determines the action of the verifier port.

 

 

• Off: The applicator port is off.

 

 

• Mode 1: Asserts the ~END_PRINT signal low while the

 

APPLICATOR PORT

printer is moving the label forward.

 

 

• Mode 2: Asserts the ~END_PRINT signal high while the

 

 

printer is moving the label forward.

 

 

• Mode 3: Asserts the ~END_PRINT signal low for 20

 

 

milliseconds when a label has been completed and

 

 

positioned. Not asserted during continuous printing modes.

 

 

• Mode 4: Asserts the ~END_PRINT signal high for 20

 

 

milliseconds when a label has been completed and

 

 

positioned. Not asserted during continuous printing modes.

 

 

NOTE: Set as suggested by the applicator manufacturer.

 

 

 

 

WEB S.

 

 

 

 

 

MEDIA S.

 

 

 

 

 

RIBBON S.

 

 

 

These parameters are automatically set during the calibration

 

 

 

MARK S.

procedure. They should only be changed by a qualified service

 

 

technician. Refer to the maintenance manual for more

 

 

information on these parameters.

 

 

 

MARK MED S.

Press the NEXT/SAVE key repeatedly to skip these

 

parameters.

 

 

 

 

 

 

MEDIA LED

 

 

 

 

 

RIBBON LED

 

 

 

 

 

MARK LED

 

 

 

 

58

Zebra XiIII-Series User’s Guide