5LEERQ5HPRYDO
Refer to Figure 25.
1.Break the ribbon as close to the ribbon take-up spindle as possible.
2.While holding the ribbon take-up spindle, turn the knob (1) clockwise until it stops. This causes the ribbon release bars to pivot down (2), easing the spindle’s “grip” on the wound ribbon.
3.Slide the ribbon off of the ribbon take-up spindle. Once the spent ribbon has been removed, ensure that the arrow on the knob aligns with the indented notch in the ribbon take-up spindle (see Figure 25 inset).
4.Remove the core from the ribbon supply spindle.
5.Follow the ribbon loading procedure on page 38 to load the new ribbon.
Figure 25
40 | Zebra XiIII-Series User’s Guide |