$GMXVWLQJ￿WKH￿8SSHU￿0HGLD￿6HQVRU

Refer to Figure 6. (For clarity, not all printer parts are shown.)

1.Remove the ribbon (if it is installed).

2.Locate the upper media sensor. The upper media sensor “eye” is directly below the adjustment screw head.

3.Slightly loosen the upper media sensor adjustment screw (use a Phillips-head screwdriver).

4.Using the tip of the screwdriver, slide the upper sensor along the slot to the desired position.

5.Secure the upper media sensor adjustment screw.

Figure 6

Zebra XiIII-Series User’s Guide