Press | Display Shows |
| Action/Explanation |
|
| Media and Ribbon Sensor Sensitivity: Press NEXT/SAVE to | |
|
| skip the calibration procedure and continue with the host port | |
|
| selection parameters that follow. Press the RIGHT BLACK OVAL | |
| MEDIA AND | key to start the calibration procedure. | |
| RIBBON | This procedure is used to adjust the sensitivity of the media and | |
| CALIBRATE | ribbon sensors. | |
|
| NOTE: The procedure must be followed exactly as presented. | |
|
|
| All steps must be performed even if only one of the |
|
|
| sensors requires adjustment. |
|
|
| |
Media and Ribbon Calibration Procedure | |||
|
|
| |
|
| Press the LEFT BLACK OVAL key to cancel the operation, or do | |
|
| the following: | |
| LOAD BACKING | 1) Open the printhead. | |
|
| 2) | Remove approximately 8" (203 mm) of labels from the media |
|
|
| roll, and pull the backing into the printer so that only the |
|
|
| backing is between the media sensors. |
|
| 3) | Press the RIGHT BLACK OVAL key to continue. |
|
|
| |
|
| Press the LEFT BLACK OVAL key to cancel the operation or do | |
|
| the following: | |
| REMOVE RIBBON | 1) Remove the ribbon. | |
|
| 2) | Close the printhead. |
|
| 3) | Press the RIGHT BLACK OVAL key to continue. |
|
|
| |
|
| The printer automatically adjusts the scale (gain) of the signals it | |
| CALIBRATING | receives from the media and ribbon sensors. On the sensor | |
| PLEASE WAIT | profile, this essentially corresponds to moving the peak of the | |
|
| graph up or down to optimize the readings for your application. | |
|
|
| |
|
| When “RELOAD ALL” is displayed: | |
|
| 1) | Open the printhead and pull the media forward until a label is |
— | RELOAD ALL | positioned under the media sensor. | |
|
| 2) | Reload the ribbon back into to its proper position. |
|
| 3) | Close the printhead. |
|
| 4) | Press the RIGHT BLACK OVAL key to continue. |
|
|
| |
|
| Now that the scale has changed, the printer performs a | |
| MEDIA AND | calibration equivalent to pressing the CALIBRATE key; during this | |
| RIBBON | process, the printer determines the label length. The process is | |
| CALIBRATE | now complete! To see the new readings on the new scale, print a | |
|
| sensor profile. | |
|
|
|
|
50 | Zebra |