CALIBRATION

 

 

PARAMETER

SELECTIONS

MEDIA POWER UP

This parameter establishes the action of the media

(password

when the printer is turned ON.

required)

 

 

Default: Calibration

 

Choices: Calibration - recalibrates media and ribbon

 

sensors by feeding labels

 

Feed - feeds the label to the first web

 

Length - determines the length of the label

 

by feeding labels

 

No Motion - media does not move

 

 

HEAD CLOSE

This parameter establishes the action of the media

(password

after the printhead has been opened and then

required)

closed.

 

Default: Calibration

 

Choices: Calibration - recalibrates media and ribbon

 

sensors by feeding labels

 

Feed - feeds the label to the first web

 

Length - determines the length of the label

 

by feeding labels

 

No Motion - media does not move

 

 

MANUAL CALIBRATE

If the auto-calibration feature has been disabled by a

 

ZPL command from the host or the HEAD CLOSE

 

parameter is not “Calibrate”, you may use this

 

feature to calibrate the media and ribbon sensors.

 

Press “+” to enable the Calibration process.

 

NOTE: If the printer is configured for continuous

 

media, no media movement will occur during

 

the Calibration process.

 

 

SENSOR PROFILE

The Media and Ribbon Sensor Profile provides a

 

graphical representation of the Media and Ribbon

 

Sensor settings as an aid to the Service Technician if

 

problems with inter-label gap sensing occur.

 

Press “+” to enable the Sensor Profile printout.

 

 

WEB S.

 

 

THESE SETTINGS SHOULD ONLY BE CHANGED

MEDIA S.

BY AN AUTHORIZED SERVICE TECHNICIAN.

 

RIBBON S.

(A password is required)

 

 

 

MEDIA LED

Refer to the Z Series Maintenance Manual for

 

additional information about these settings.

RIBBON LED

 

 

 

Continued on the following page.