Prestige 202H User’s Guide

speed of the console port will be reset to the default of 9600bps with 8 data bit, no parity, one stop bit and flow control set to none. The password will be reset to “1234”, also.

3.7.1 Uploading a Configuration File Via Console Port

Step 1. Download the default configuration file from the ZyXEL FTP site, unzip it and save it in a folder.

Step 2. Turn off the Prestige, begin a terminal emulation software session and turn on the Prestige again. When you see the message "Press Any key to enter Debug Mode within 3 seconds", press any key to enter debug mode.

Step 3. Enter "atlc" after "Enter Debug Mode" message.

Bootbase Version: V1.03 3/18/1999 15:04:51

RAM: Size = 4096 Kbytes

FLASH: Intel 8M

ZyNOS Version: V2.30a00 5/5/1999 9:37:32

Press any key to enter debug mode within 3 seconds.

........................................

Enter Debug Mode atlc

Now erase flash ROM for upload

Figure 3-5 Resetting the Router

Step 4. Wait for the "Starting XMODEM upload" message before activating Xmodem upload on your

terminal. This is an example Xmodem configuration upload using HyperTerminal.

Introducing the SMT

3-7