| Chapter 7 Basic Setting |
| Table 8 Basic Setting > System Info (continued) | |
| LABEL | DESCRIPTION |
| Current | This field displays this fan's current speed in Revolutions Per Minute (RPM). |
|
|
|
| MAX | This field displays this fan's maximum speed measured in Revolutions Per Minute |
|
| (RPM). |
|
|
|
| MIN | This field displays this fan's minimum speed measured in Revolutions Per Minute |
|
| (RPM). "<41" is displayed for speeds too small to measure (under 2000 RPM). |
|
|
|
| Threshold | This field displays the minimum speed at which a normal fan should work. |
|
|
|
| Status | Normal indicates that this fan is functioning above the minimum speed. Error |
|
| indicates that this fan is functioning below the minimum speed. |
|
|
|
| Voltage(V) | The power supply for each voltage has a sensor that is capable of detecting and |
|
| reporting if the voltage falls out of the tolerance range. |
|
|
|
| Current | This is the current voltage reading. |
|
|
|
| MAX | This field displays the maximum voltage measured at this point. |
|
|
|
| MIN | This field displays the minimum voltage measured at this point. |
|
|
|
| Threshold | This field displays the percentage tolerance of the voltage with which the Switch still |
|
| works. |
|
|
|
| Status | Normal indicates that the voltage is within an acceptable operating range at this |
|
| point; otherwise Error is displayed. |
|
|
|