Chapter 21 VLAN Stacking
Table 54 Advanced Application > VLAN Stacking (continued)
LABEL | DESCRIPTION |
Role | Select Access Port to have the Switch add the SP TPID tag to all incoming |
| frames received on this port. Select Access Port for ingress ports at the edge |
| of the service provider's network. |
| Select Tunnel Port (available for Gigabit ports only) for egress ports at the |
| edge of the service provider's network. |
| In order to support VLAN stacking on a port, the port must be able to allow |
| frames of 1526 Bytes (1522 Bytes + 4 Bytes for the second tag) to pass |
| through it. |
|
|
SPVID | SPVID is the service provider’s VLAN ID (the outer VLAN tag). Enter the |
| service provider ID (from 1 to 4094) for frames received on this port. See |
| Chapter 8 on page 79 for more background information on VLAN ID. |
|
|
Priority | On the Switch, configure priority level of inner IEEE 802.1Q tag in the Port |
| Setup screen. |
| "0" is the lowest priority level and "7" is the highest. |
|
|
Apply | Click Apply to save your changes to the Switch’s |
| loses these changes if it is turned off or loses power, so use the Save link on |
| the top navigation panel to save your changes to the |
| when you are done configuring. |
|
|
Cancel | Click Cancel to begin configuring this screen afresh. |
|
|
174 |
| |
| ||
|
|
|