Chapter 13 Remote Management

13.1.1 Remote Management Limitations

Remote management over LAN or WAN will not work when:

1You have disabled that service in one of the remote management screens.

2The IP address in the Secured Client WAN IP Address field does not match the client IP address. If it does not match, the NBG-418N will disconnect the session immediately.

3There is already another remote management session with an equal or higher priority running. You may only have one remote management session running at one time.

4There is a firewall rule that blocks it.

13.1.2Remote Management and NAT

When NAT is enabled:

Use the NBG-418N’s WAN IP address when configuring from the WAN.

Use the NBG-418N’s LAN IP address when configuring from the LAN.

13.1.3System Timeout

There is a default system management idle timeout of five minutes (three hundred seconds). The NBG-418N automatically logs you out if the management session remains idle for longer than this timeout period. The management session does not time out when a statistics screen is polling. You can change the timeout period in the System screen.

13.2 WWW Screen

To change your NBG-418N’s World Wide Web settings, click Management > Remote MGMT to display the WWW screen.

Figure 81 Management > Remote MGMT > WWW

116

 

NBG-418N User’s Guide