ZyXEL

VES-1616/24FA-5x Series Support Notes

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None:

5.After you are connected successfully, the login prompt displays. Enter the administrator login username (“admin”) and password (“1234” is the default).

6.Enter “config” to go into the configuration mode.

7.Enter the commands as shown in the screen to configure VLAN 1 on switches A, E, F and H for this network scenario. (Port 17 will be tagged during Egress)

8.After entering the commands, use the “write memory” command in the enable mode to save your configuration.

Configuring Switch B Using the CLI

1.Connect your computer to the console port on the switch.

2.Open a Terminal program (for example Hyper Terminal in Windows)

3.Configure the console port settings as shown next.

Bps: 9600

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None:

4.After you are connected successfully, the login prompt displays. Enter the administrator login username (“admin”) and password (“1234” is the default).

5.Enter “config” to go into the configuration mode.

6.Enter the commands as shown in the screen to configure VLAN Stacking on