Configuring the Switch Using the CLI

ZyXEL

VES-1616/24FA-5x Series Support Notes

13. PING PC C from PC A (not successful with request timed out message)

Configuring the Switch Using the CLI

1.Connect the your computer to the console port on the switch

2.Open your Terminal program (for example, Hyper Terminal in Windows System).

3.Make sure the console connection settings are configured as listed below. Bps: 9600

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None:

4.After you can connect successfully, enter the user name and password.

5.Enter “config” to go into the configuration mode.

6.Enter the following commands to configure Port Based VLAN on your Switch in this network example.