VES-1616/24FA-5x Series Support Notes

Enabled VLAN Stacking

Port 1 is connected to port 17 on Switch F

Port 25 is connected to port 27 on Switch C

Switch H:

Enabled VLAN, VLAN1, and egress tagging on Port 17

Port 1 is connected to another access switch in the building.

Port 17 is connected to port 2 on Switch B

Configuring Switch A, E, F and H Using the Web Configurator

On switches A, E, F and H, create a VLAN (with VID 1) which contains all the port members. By default VLAN1 is already created for you. The setting required is to make sure that port 17 is a member of VLAN 1 and that egress tagging is enabled on the port.

*By default all the ports in VLAN 1 are untagged during Egress.

Configuring Switch B Using the Web Configurator

1.Use an RJ-45 Ethernet cable to connect your computer to the MGMT port on the switch.

2.By default, the IP address on the MGMT port is 192.168.0.1/24

3.Set your computer to use a static IP address in the same subnet (for example, 192.168.0.2/24).

4.Open a web browser (such as IE) and enter http://192.168.0.1 as the URL.

5.A login screen displays. Enter “admin” (the default) as the username and “1234” (the default) as the password.

6.After you have logged in successfully, the main screen displays as shown.