NaviTrack® II
Chart 1 Troubleshooting
PROBLEM | PROBABLE FAULT LOCATION | ||
|
|
|
|
The NaviTrack II locks up |
| Turn the unit OFF, and then back ON. Remove the batteries if the unit will not turn off. If batteries are | |
during use. |
|
| low, replace them. |
NaviTrack II will not pick |
| Check that the correct mode and frequency is set. Examine circuit for possible improvements. Relocate | |
up the signal. |
|
| transmitter, change grounding, frequency, etc. |
While tracing, lines are |
| This indicates that the NaviTrack II is not picking up the signal or there is interference. | |
“jumping” all over the |
| Make sure that the transmitter is well connected and grounded. Point the NaviTrack II at either lead to be | |
screen in the mapping |
| ||
| sure that there is a complete circuit. | ||
display. |
| ||
| Try a higher frequency, or connecting to a different point in the line, or switching to inductive mode. | ||
|
|
| |
|
|
| Try to determine the source of any noise and eliminate it (Bonded, grounding, etc.). |
|
|
|
|
While locating a Sonde, |
| Check the batteries in the Sonde to see that they are working. | |
lines are “jumping” all |
| Sonde may be too far away; try starting with it closer in if possible, or do an area search. | |
over the screen. |
| ||
| Verify signal by placing lower antenna close to Sonde. NOTE – Sondes have difficulty emitting signals | ||
|
|
| |
|
|
| through cast iron and ductile iron lines. |
|
|
|
|
Distance between Sonde |
| Sonde may be tilted or there may be a cast iron to plastic transition. | |
and Poles is not equal. |
|
|
|
Unit acts erratic, won’t |
| Batteries may be low. Replace with fresh batteries and turn ON. | |
power down. |
|
|
|
Display appears |
| Power the unit OFF and then back ON. | |
completely dark, or |
|
| |
completely light when |
| Adjust the LCD screen contrast. | |
it is turned ON. |
|
| |
|
| ||
There is no sound. |
| Adjust the sound level in the sound menu. Verify Proximity Signal is greater than zero. | |
|
|
|
|
NaviTrack II will not turn |
| Check orientation of batteries. | |
ON. |
| Check that the batteries are charged. | |
|
|
| |
|
|
| Check to see that the battery contacts are OK. |
|
|
| Unit may have blown a fuse (Factory service is required). |
When using 93kHz |
|
| |
frequency the detector |
|
| |
does not receive |
| Try setting the receiver to the | |
a signal. |
|
|
|
32 | Ridge Tool Company |