Chromalox 1604-7 user manual Linear Inputs, Logic Input

Page 31

STANDARD RANGES TABLE

T/C

 

 

 

Ranges

 

 

type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

0

0 /+ 400.0°C

 

 

 

---

L

1

0 /+ 900

°C

20

0

/ + 1650 °F

J

2

-100.0/ + 400.0°C

 

 

 

---

J

3

-100

/ + 1000 °C

21

-150 / + 1830 °F

K

4

-100.0/ + 400.0°C

 

 

 

---

K

5

-100

/+ 1370 °C

22

-150 / + 2500 °F

T

6

-199.9/ + 400.0°C

23

-330 / + 750

°F

N

7

-100

/+ 1400

°C

24

-150 / + 2550 °F

R

8

0

/+ 1760

°C

25

0

/ + 3200

°F

S

9

0

/+ 1760

°C

26

0

/ + 3200

°F

 

 

 

 

 

 

 

 

 

B)RTD (Resistance Temperature Detector) Input: for RTD Pt 100 W, 3-wire connection. Input circuit: current injection.

°C/°F selection: via front pushbuttons or serial link.

Line resistance: automatic compensation up to 20 W/wire with no measurable error. Calibration: according to DIN 43760 Burnout: up scale. NOTE: a special test is

provided to signal OVERRANGE when input resistance is less than 15 W.

STANDARD RANGES TABLE

Input

 

Ranges

 

type

 

 

 

 

 

 

 

 

 

 

 

 

10

- 199,9

/ + 400,0

°C

RTD Pt 100 W

11

- 200

/ + 800

°C

DIN 43760

27

-199,9

/ +400,0

°F

 

28

-330 / + 1470

°F

 

 

 

 

 

C) LINEAR INPUTS

Read-out: keyboard programmable between -1999 and +4000.

Decimal point: programmable in any position.

Burn out: the instrument shows the burn out condi- tion as an underrange condition for 4-20 mA, 1-5 V and 2-10 V input types.

It shows the burn out condition as an underrange or an overrange condition (selectable by soldering jumper) for 0-60 mV and 12-60 mV input types. No indication are available for 0-20 mA, 0-5 V and 0-10 V input types.

 

Input type

 

impedance

Accuracy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

0 - 60 mV

> 1 MW

 

13

 

12

- 60 mV

 

 

 

 

 

14

 

0 - 20 mA

< 5

W

 

15

 

4 - 20 mA

0.2 % + 1 digit

 

 

 

16

 

0

-

5 V

> 200 kW

@ 25°C

17

 

1

-

5

V

 

 

 

 

 

18

 

0

- 10

V

> 400 kW

 

19

 

2

- 10

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D) LOGIC INPUT

The instrument is equipped with one input from contact (voltage free) for setpoint selection. Contact open = Main setpoint.

Contact closed = Auxiliary setpoint.

NOTES

1)Use an external contact with a contact rating better than 0.5 mA, 5 V DC.

2)The instrument needs 100 ms to recognize a contact status variation.

3)The logic inputs are NOT isolated by the measuring input.

28

1604-7-1-AB.p65

28

5/16/00, 10:50 AM

Image 31
Contents Chromalox Contents III Model identificationScrew Mounting RequirementsOutline and CUT-OUT Dimensions Outline and CUT OUT DimensionsMeasuring Inputs TC Input Connection DiagramsLinear Input RTD InputRelay Outputs Logic Input Safety noteOUT Linear Output Inductive LoadsLoad Operating Voltage Serial Interface Power Line WiringWhen the Neutral line is present, connect it to terminal Open Input Circuit Preliminary Hardware SettingsInput Type TC-RTDSEr4 = Byte format for serial link SEr1 = Serial interface protocolOFF SEr3 = Baude rate for serial linkP5 = Output 1 function P2 = Decimal point positionP3 = Initial scale value P4 = Full scale valueP9 = Output 2 function. nonE = output not used P10 = Alarm 1 operating modeP7 = analog retransmission initial scale value P8 = analog retransmission full scale valueP14 = Alarm 2 threshold value P12 = Alarm 2 operating modeP15 = Alarm 2 hysteresis value P22 = Cooling media P19 = Displayed value of the main power outputP18 = Main control output action P20 = Secondary control output actionP29 = Displayable protected parameters P24 = Alarm 1 actionP26 = Alarm 2 action P28 = Offset adjustment added to the measured valueP38 = Output safety value P36 = Timeout selectionP34 = Manual function P43 = Set point indication P41 = Control action typeP44 = Operative set point alignment at instrument start up Display Function IndicatorsREM SP2 MAN SP SP2 Selection MAN =Manual Function Direct Access to SET PointLamp Test Serial Link Smart functionAL2 Alarm 2 threshold RSt Manual reset of the alarmsAL1 Alarm 1 threshold HSA1 Alarm 1 hysteresisIntegral time Output 3 cycle timeHysteresis for ON/OFF control action Relative Cooling gainGrd1 Ramp applied to an increasing set point change TOL Time duration of the output power limiter soft startUnderrange Error MessagesError Messages OverrangeError List General Informations General SpecificationsInputs Thermocouple Logic Input Linear InputsControl Actions SET PointsOutputs Output AlarmsSerial Communication Interface MaintenanceStop bit one Address HSA1, HSA2 Appendix a Default ParametersParameter Default Value = OFFER0 ParaP44 Appendix A.3 Appendix A.4 Emerson Electric CO Chromalox