GENERAL INFORMATIONS
GENERAL SPECIFICATIONS
Case: Polycarbonate grey dark color;
guishing degree:
Front protection - designed and tested for IP 65 (*) and NEMA 4X (*) for indoor locations (when panel gasket is installed).
(*)Test were performed in accordance with CEI 70- 1 and NEMA
Installation: panel mounting.
Rear terminal block: 15 screw terminals ( screw M3, for cables from f 0.25 to f 2.5 mm2 or from AWG 22 to AWG 14 ) with connection diagrams and safety rear cover.
Dimensions: DIN 43700 48 x 48 mm, depth 122 mm.
Weight: 250 g. Power supply:
- 100V to 240V AC 50/60Hz
- 24 V AC/DC (+ 10 % of the nominal value).
Power consumption: 6 VA max.
Insulation resistance: > 100 MW according to IEC
Dielectric strength: 1500 V rms according to IEC
Display updating time: 500 ms.
Sampling time: 250 ms for linear inputs
500 ms for TC and RTD inputs. Resolution: 30000 counts.
Accuracy: + 0,2% f.s.v.. + 1 digit @ 25 °C ambient temperature.
Common mode rejection: 120 dB @ 50/60 Hz.
Normal mode rejection: 60 dB @ 50/60 Hz.
Electromagnetic compatibility and safety requirements: This instrument is marked CE. Therefore, it is conforming to council directives 89/336/EEC (reference harmonized standard
EN
Temperature drift: (CJ excluded)
<200 ppm/°C of span for mV and TC ranges 1, 3, 5, 7, 20, 21, 22, 24.
<300 ppm/°C of span for mA/V
<400 ppm/°C of span for RTD range 11, 28 and TC range 0, 2, 4, 6, 23.
<500 ppm/°C of span for RTD range 10 and TC ranges 8, 9, 25, 26.
<800 ppm/°C of span for RTD range 27. Operative temperature: from 0 to 50 °C. Storage temperature :
1) WATCH DOG circuit for automatic restart.
2) DIP SWITCH for protection against tampering of configuration and calibration parameters.
INPUTS
A) THERMOCOUPLE
Type : L
External resistance: 100 W max, maximum error 0,1% of span.
Burn out: It is shown as an overrange condition (standard). It is possible to obtain an underrange indication by cut and short.
Cold junction: automatic compensation from 0 to 50 °C.
Cold junction accuracy : 0.1 °C/°C
Input impedance: > 1 MW
Calibration : according to IEC
27
27 | 5/16/00, 10:50 AM |