Five Star Sr200na, Sr200lp,, Sr333na, Sr333lp,, Sr400na, Sr400lp owner manual Minimum Height

Page 13

6.See Table 4 for height of vent termination above the roof.

7.Do not run the heater vent into a common vent with any other appliance.

8. Fire Hazard. Do not vent the heater directly into a masonry chimney. Installation into a masonry chimney must use a chimney liner and must meet National Fuel Gas Code requirements and all local code requirements.

Table 4: Vent Termination Height vs. Roof Pitch

 

Minimum Height

Roof Pitch

Above Roof*

 

 

Flat to 6/12

1 Ft.

6/12 to 7/12

1 Ft. 3 in.

>7/12 to 8/12

1 Ft. 6 in.

>8/12 to 9/12

2 Ft.

>9/12 to 10/12

2 Ft. 6 in.

>10/12 to 11/12

3 Ft. 4 in.

>11/12 to 12/12

4 Ft.

>12/12 to 14/12

5 Ft.

>14/12 to 16/12

6 Ft.

>16/12 to 18/12

7 Ft.

>18/12 to 20/12

7 Ft. 6 in.

>20/12 to 21/12

8 Ft.

* Vent must be at least eight (8) feet away from nearest vertical surface. Vents extending five (5) feet or more above the roof must be braced or guyed. Consult your local code officials for detailed information.

Listed

Termination

Cap

Min. 8 Ft.

See Table 4

Storm Collar

For Min. Hght.

Flashing

6" Minimum Clearance to

Combustible Materials

HORIZONTAL OR VERTICAL VENTING - POSITIVE PRESSURE (SPECIAL GAS VENTING)

(See Figures 13 and 14)

Vent the heater either horizontally or vertically using one of the 4-inch Special Gas Vent Pipes listed on Page 14 (Table 5). Install the vent pipe in accordance with local codes and the provisions of the National Fuel Gas Code, ANSI Z223.1, and the vent manufacturer’s instructions. Do not use a draft hood with this heater. Use one of the special gas vents specified in Table 5 (Page 14) for positive- pressure venting of this heater – do not use any other vent with it. Install the vent according to the vent manufactur- er’s detailed instructions.

Maintain clearance between the vent pipe and combustible surfaces according to the vent manufacturer’s instructions and code requirements. Do not place any insulating mate- rials around the vent or inside the required clear air space surrounding the vent. See Table 6 (Page 15) for maximum permissable vent lengths. See Table 7 (Page 15) for Listed vent components.

CONNECTING SPECIAL GAS

VENT TO THE HEATER

Metallic:

1.Order an Appliance Adapter kit:

Sta-Rite Part No. 77707-0086 for Saf-T Vent® or Saf-T Vent® CI.

Sta-Rite Part No. 77707-0087 for Z-Vent.

2.Remove the outside vent cover.

3.Install the Appliance Adapter in the Vent Body of the heater (located under the outside Vent Cover). Before connecting the Appliance Adapter to the Vent Body, wet a clean cloth or paper towel with isopropyl alco- hol (rubbing alcohol) and vigorously wipe the socket of the Vent Body. Immediately wipe the cleaned sur- faces dry with a clean cloth or paper towel. Repeat for the exterior of the heater end of the Appliance Adapter. Attach the Appliance Adapter to the vent body using the adhesive specified by the vent manufacturer, fol- lowing the vent manufacturer’s instructions.

Risk of carbon monoxide poisoning if adapter is improperly attached. Mechanical connections (such as screws) can cause cracking and leaks in the adapter. Do not drill holes or use screws to connect the appliance adapter to the heater vent body. Attach with manufacturer’s specified adhesive.

Class B Double Wall

Metal Vent Pipe

Metal Flue

Firestop

Risk of fire or asphyxiation if vent is not assembled according to manufacturer’s instructions or if

Vent

Collar

Support Vertical

vent parts from different manufacturers are mixed. Vent

Body

Vent Pipe so adapter does not take weight of pipe.

parts from different manufacturers ARE NOT interchange- able. Mixing parts from more than one manufacturer may cause leaks or damage to vent. When installing a vent, pick one manufacturer and be sure that all vent parts come

FIGURE 12: Typical Metal Vent Pipe Installation (Vertical – Negative Pressure)

from that manufacturer and are specified by the manufac- turer for your system. Follow manufacturer’s instructions and local and National Fuel Gas Code requirements care- fully during assembly and installation.

13

Image 13
Contents Sta-Rite Pool/Spa Group Special Instructions to OwnerTo Consumer To InstallerSafety Instructions OWNER’S Operating Instructions Description of the HeaterSequence of Operation START-UP and OperationWhat to do if YOU Smell GAS SPA Temperature CautionOperating Instructions Operating Control To Turn OFF GAS to the ApplianceAfter START-UP Maintenance Instructions Care and MaintenancePutting the Heater Into Service Installation InstructionsOutdoor Installation Instructions Heater Clearances Outdoor Installation in a Garage Or Utility Room Indoor Installation Instructions Control Panel Indexing Heater Clearances IndoorCombustion and Ventilation AIR Supply Indoor Vent InstallationOutside Vent Cover Removal Metal Flue Collar Sta-Rite Part No Vertical Venting Negative PressureMin. Height Minimum Height Connecting Special GAS Vent to the HeaterRoof Pitch Above Roof Brand Manufacturer Material Type Sealant MinSpecial Gas Vent Vertical or Horizontal No. of 90 Elbows Water ConnectionsCool Water Water PipingWater Chemistry Water Flow RateModel Minimum Flow Maximum Flow 200 120 333 400 Chemical ValuesPressure Relief Valve Water Pressure SwitchConnect Gas Valve to End Cap Air Orifice Supplying Power to the Heater Pressure TestingElectrical Wiring GAS ConnectionsFuse FIREMAN’S Switch ConnectionMax Temperature Set Point Controls Maximum Temperature SET PointDoes red Service Initial TroubleshootingHeater LED come Start Heater Will Not Fire aContinue Heater Will Not Fire BHeater Will Not Fire C Heater Will Not Fire D Do not jumper a safety switch to remedy a failed switch Diagnostic LED’s AGS, AFS, HLS, PS, ThermistorSFS on Diagnostic LED’s SFSHeat Exchanger Troubleshooting Burner TroubleshootingRepair Parts are available from your Sta-Rite dealer 2692 Repair Parts Burner System Repair Parts Water System Repair Parts Electrical System Pool Heater Wiring Connection Diagram Pool Heater Electrical Schematic Ladder Diagram Page Page Warranty Registration Card