Five Star Sr200na, Sr200lp,, Sr333na, Sr333lp,, Sr400na, Sr400lp Heater Will Not Fire D

Page 27

Heater Will Not Fire - D

Start

Gas flows during igni- tion try, but burner does not fire.

YES

Check for 120 VAC at Igniter leads during ignition try.

NO

Check for 120 VAC between S1 and S2 terminals on Ignition Control Module during ignition try.

NO

Check for 120 VAC between L1 and L2 terminals on Ignition Control Module.

YES

Replace Ignition

Control Module.

NO

YES

YES

NO

Go back to chart “HEATER WILL NOT FIRE-C” (Page 26).

Check gas pressure? OK?

Fix wiring between S1 and S2 terminals on Ignition Control Module and HSI Igniter.

Fix wiring between L1 and L2 terminals on Ignition Control Module and Terminal Board.

YES

NO

Replace HSI Igniter.

Replace gas line with larger line or replace regulator.

27

Image 27
Contents Sta-Rite Pool/Spa Group Special Instructions to OwnerTo Consumer To InstallerSafety Instructions START-UP and Operation Description of the HeaterOWNER’S Operating Instructions Sequence of OperationSPA Temperature Caution What to do if YOU Smell GASOperating Instructions Operating Control To Turn OFF GAS to the ApplianceAfter START-UP Maintenance Instructions Care and MaintenanceHeater Clearances Outdoor Installation InstructionsPutting the Heater Into Service Outdoor Installation InstructionsHeater Clearances Indoor Indoor Installation InstructionsInstallation in a Garage Or Utility Room Control Panel IndexingIndoor Vent Installation Combustion and Ventilation AIR SupplyOutside Vent Cover Removal Vertical Venting Negative Pressure Metal Flue Collar Sta-Rite Part NoMin. Height Connecting Special GAS Vent to the Heater Minimum HeightRoof Pitch Above Roof Brand Manufacturer Material Type Sealant MinSpecial Gas Vent Vertical or Horizontal No. of 90 Elbows Water ConnectionsCool Water Water PipingChemical Values Water Flow RateWater Chemistry Model Minimum Flow Maximum Flow 200 120 333 400Pressure Relief Valve Water Pressure SwitchConnect Gas Valve to End Cap Air Orifice GAS Connections Pressure TestingSupplying Power to the Heater Electrical WiringFuse FIREMAN’S Switch ConnectionMax Temperature Set Point Controls Maximum Temperature SET PointInitial Troubleshooting Does red ServiceHeater LED come Start Heater Will Not Fire aContinue Heater Will Not Fire BHeater Will Not Fire C Heater Will Not Fire D Do not jumper a safety switch to remedy a failed switch Diagnostic LED’s AGS, AFS, HLS, PS, ThermistorSFS on Diagnostic LED’s SFSHeat Exchanger Troubleshooting Burner TroubleshootingRepair Parts are available from your Sta-Rite dealer 2692 Repair Parts Burner System Repair Parts Water System Repair Parts Electrical System Pool Heater Wiring Connection Diagram Pool Heater Electrical Schematic Ladder Diagram Page Page Warranty Registration Card