Five Star Sr200na, Sr200lp,, Sr333na, Sr333lp,, Sr400na, Sr400lp Warranty Registration Card

Page 40

STA-RITE LIMITED WARRANTY

Pumps, filters, skimmers, underwater lights (except bulbs), accessories and fittings manufactured by Sta-Rite are war- ranted to be free of defects in material and workmanship for one (1) year from date of installation.

Product specific warranties:

Year from date

of installation

 

 

 

HRPB, DEPB, System 3, and PL – Tanks

. . . . . . .10 years

Internal filter components and valves

. . . . . . . . 1 year

Max-E-Therm– Pool/Spa Heaters . . . . . . . . . . . . 2 years Heater Enclosure only (Upper RH & LH;

lower enclosure; and control board enclosure)…10 years

Automatic Pool Cleaners including Hose . . . . . . 2 years

Cristal-Flo filters – Tanks . . . . . . . . . . .10 years pro-rated* Valve and internal components. . . . . . . . . . . . . . 1 year

Posi-Flo II – Tanks . . . . . . . . . . . . . . . . . . . . . . . .10 years Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year

PRC Cartridge

Filter Tanks . . . . . . . . .5 years pro-rated (1st 2 years full) Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year

System 3 Above Ground Systems – Tanks .

. . . . .10 years

Pumps / Platform and Internals

. . . . . . 1 year

Pumps

. . . . . . 1 year

When equipped with A.O. Smith

 

2-compartment motors (Does not include

 

pumps sold as part of a systems package)

. . . . . 2 years

Traps / In-Line Strainers

. . . . . . 1 year

Vertical Commercial Filter – Tanks . . . . . . . . . . .10 years Internals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year

Horizontal Commercial Filter

Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 years (Years 6-9, Prorated declining 20%/year,Yr. 10 - 10%) Internals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year

*Full warranty coverage is in effect for one year after instal- lation. The pro-rated warranty covers the tank only during the 2nd through 10th year after installation.The amount cov- ered decreases by 10% each year. (ie., 2nd year 90% covered, 3rd year 80% covered, etc.).

The foregoing warranties relate to the original consumer purchaser (“Purchaser”) only. Sta-Rite shall have the option to repair or replace the defective product, at its sole discre-

tion. Purchasers must pay all labor and shipping charges necessary to replace the product covered by this warranty. Requests for warranty service must be made through the installing dealer. This warranty shall not apply to any prod- uct that has been subject to negligence, misapplication, improper installation or maintenance, or other circum- stances which are not in Sta-Rite’s direct control.

This warranty sets forth Sta-Rite’s sole obligation and Purchaser’s exclusive remedy for defective products.

STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WAR- RANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of inci- dental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclu- sion may not apply to you.This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Supersedes all previous publications.

Sta-Rite Industries, Inc.,

293 Wright St., Delavan, WI 53115

Retain Warranty Certificate (upper portion) in a safe and convenient location for your records.

DETACH HERE: Fill out bottom portion completely and mail within 10 days of purchase/installation to:

Sta-Rite, Attn: Warranty Dept., 293 Wright St., Delavan, WI 53115

Warranty Registration Card

Name

Address

City

 

State

Zip

 

Purchase Date

 

 

 

 

 

 

 

 

Product Purchased

 

 

 

 

 

 

New installation

Replacement

 

 

 

 

 

 

Type of Pool

Inground

Vinyl

Fiberglass

Gunite

 

 

 

 

 

Size of Pool

 

 

 

 

 

 

 

 

 

Years pool has been in service less than 1 1-3 3-5 5-10

Purchased from:

Company name

Address

CityStateZip

Please send me more information on these

other products from Sta-Rite.

Pumps Filters Automatic Pool Cleaners Maintenance Equipment Test Strips

Heaters

S4877PS (Rev. 1/22/01)

Image 40
Contents Special Instructions to Owner Sta-Rite Pool/Spa GroupTo Installer To ConsumerSafety Instructions Description of the Heater OWNER’S Operating InstructionsSequence of Operation START-UP and OperationWhat to do if YOU Smell GAS SPA Temperature CautionOperating Instructions To Turn OFF GAS to the Appliance Operating ControlAfter START-UP Care and Maintenance Maintenance InstructionsInstallation Instructions Putting the Heater Into ServiceOutdoor Installation Instructions Heater Clearances OutdoorIndoor Installation Instructions Installation in a Garage Or Utility RoomControl Panel Indexing Heater Clearances IndoorCombustion and Ventilation AIR Supply Indoor Vent InstallationOutside Vent Cover Removal Metal Flue Collar Sta-Rite Part No Vertical Venting Negative PressureMin. Height Minimum Height Connecting Special GAS Vent to the HeaterRoof Pitch Above Roof Min Brand Manufacturer Material Type SealantWater Connections Special Gas Vent Vertical or Horizontal No. of 90 ElbowsWater Piping Cool WaterWater Flow Rate Water ChemistryModel Minimum Flow Maximum Flow 200 120 333 400 Chemical ValuesWater Pressure Switch Pressure Relief ValveConnect Gas Valve to End Cap Air Orifice Pressure Testing Supplying Power to the HeaterElectrical Wiring GAS ConnectionsFIREMAN’S Switch Connection FuseMaximum Temperature SET Point Max Temperature Set Point ControlsDoes red Service Initial TroubleshootingHeater LED come Heater Will Not Fire a StartHeater Will Not Fire B ContinueHeater Will Not Fire C Heater Will Not Fire D Diagnostic LED’s AGS, AFS, HLS, PS, Thermistor Do not jumper a safety switch to remedy a failed switchDiagnostic LED’s SFS SFS onBurner Troubleshooting Heat Exchanger TroubleshootingRepair Parts are available from your Sta-Rite dealer 2692 Repair Parts Burner System Repair Parts Water System Repair Parts Electrical System Pool Heater Wiring Connection Diagram Pool Heater Electrical Schematic Ladder Diagram Page Page Warranty Registration Card