Five Star Setting Maximum Temperatures for Your SR400LP Swimming Pool Heater

Page 22

6. Reinstall and bolt up the jacket halves.

The fuse for the Fireman’s Switch is 1.25 amp 1-1/4x1/4” fast blow fuse, available locally.

MAXIMUM TEMPERATURE SET POINT

1.Unbolt and remove upper jacket halves (see Figure 3, Page 5).

2.Depress clips and remove control board assembly dome (see Figure 9, Page 10).

3.Push the Max. Temp. Set Point button on the back of the control board (see Figure 26). The following sequence should happen:

SET MAX

S1

SET MAX

S1

FIGURE 26: Max Temperature Set Point Controls

A. The unit will come on and the POOL ON light will come on.

B. Press the ▼Temp or ▲Temp pad (on TOP of the panel) to set maximum pool temperature.

C. Wait 30 seconds; the POOL ON light will go off and the SPA ON light will come on.

D. Press the ▼Temp or ▲Temp pad (on TOP of the panel) to set maximum spa temperature (set temper- ature to 104° F or less).

E.Wait 30 seconds; the SPA ON light will go off and the unit will shut down.

4.Reinstall and bolt up the jacket halves.

22

Image 22
Contents Special Instructions to Owner Sta-Rite Pool/Spa GroupTo Installer To ConsumerSafety Instructions Sequence of Operation Description of the HeaterOWNER’S Operating Instructions START-UP and OperationWhat to do if YOU Smell GAS SPA Temperature CautionOperating Instructions To Turn OFF GAS to the Appliance Operating ControlAfter START-UP Care and Maintenance Maintenance InstructionsOutdoor Installation Instructions Installation InstructionsPutting the Heater Into Service Heater Clearances OutdoorControl Panel Indexing Indoor Installation InstructionsInstallation in a Garage Or Utility Room Heater Clearances IndoorCombustion and Ventilation AIR Supply Indoor Vent InstallationOutside Vent Cover Removal Metal Flue Collar Sta-Rite Part No Vertical Venting Negative PressureMin. Height Minimum Height Connecting Special GAS Vent to the HeaterRoof Pitch Above Roof Min Brand Manufacturer Material Type SealantWater Connections Special Gas Vent Vertical or Horizontal No. of 90 ElbowsWater Piping Cool WaterModel Minimum Flow Maximum Flow 200 120 333 400 Water Flow RateWater Chemistry Chemical ValuesWater Pressure Switch Pressure Relief Valve Connect Gas Valve to End Cap Air Orifice Electrical Wiring Pressure TestingSupplying Power to the Heater GAS ConnectionsFIREMAN’S Switch Connection FuseMaximum Temperature SET Point Max Temperature Set Point ControlsDoes red Service Initial TroubleshootingHeater LED come Heater Will Not Fire a StartHeater Will Not Fire B ContinueHeater Will Not Fire C Heater Will Not Fire D Diagnostic LED’s AGS, AFS, HLS, PS, Thermistor Do not jumper a safety switch to remedy a failed switchDiagnostic LED’s SFS SFS onBurner Troubleshooting Heat Exchanger TroubleshootingRepair Parts are available from your Sta-Rite dealer 2692 Repair Parts Burner System Repair Parts Water System Repair Parts Electrical System Pool Heater Wiring Connection Diagram Pool Heater Electrical Schematic Ladder Diagram Page Page Warranty Registration Card